SPF OVER METAL ROOFS

SPF OVER METAL ROOFS
Weatherizing and insulation system

Weatherproofing – Roof-Tek SPF over metal has the longevity that an owner requires, these system have 30 years of proven performance. The seamless spray foam insulation has no joints or fasteners to ever leak. And offering additional protection is the liquid applied membrane, which can be silicone, acrylic or urethane. All Roof- Tek coatings are elastomeric and are suitable for various climates. Silicones have been used extensively and offer superior resistance to UV. Our coating systems are sustainable, and in the future they can be simply and easily recoated, with low cost and no wasted materials. The materials are fully bonded and adhered to the metal substrate, so they offer excellent resistance to wind damage. And they perform without the thousands of penetrating fasteners other recover systems require. If rust has started on the roofs; these systems will seal the metal from the conditions that cause rust.

Movement – Movement can tear apart a metal roof, stressing seams, fatiguing fasteners and causing seals and flashings to fail, the superior insulating properties of the SPF will control this movement. By insulating metal roofs from the top side, expansion and contraction are reduced; also the panels are strengthened by the full adhesion of the rigid, higher-density, spray foam insulation. All fasteners and flashings are resealed with the seamless SPF.

Picture shows SPF insulated roof system installed over an existing,
pre-engineered metal panel roof.

SPF Over Metal Roofing

The Roof-Tek® product line has decades of
experience with the restoration of metal roofing and
metal building components. Our systems offer
numerous benefits to the building owner, ones that can
actually make a ‘pre-engineered’ metal roof better than
the original design.
Metal roofs experience excessive movement due to
heat cycling (expansion with warming and contraction
with cooling.) Metal roofs and buildings frequently have
additional movement from their light-weight structural
design. In many buildings the amount of insulation is
below the current design standard, causing these
buildings to be very uncomfortable and very expensive
to heat and cool.
With the construction of numerous metal buildings and
metal roofs in the 80’s and 90’s, many owners have
facilities now developing problems and requiring
attention. Roof-Tek’s SPF over metal system is the
answer. Coating & Foam Solutions, LLC. supplies

Features

 

  •  Proven leak free performance
  •  Lightweight and long-lasting
  •  Seamless design
  •  Wind resistant with no fasteners
  •  Energy savings and payback
  •  Low life-cycle and maintenance costs
  •  Fast installation with low labor costs

 

Available credentials:

  • UL Listed
  • ENERGY STAR® listed coatings
  • CRRC (Cool Roof Rating Council) listed coatings
  • Dade County Approved
  • VOC Compliant
  • California Title 24
  • FM Approved

Before an installation you need to evaluate the condition of the current roofing system. If there are leaks, why do they occur? If you are not able to thoroughly investigate these conditions, hire a professional, to do what you need to have accomplished. The SPF System is very efficient, environmentally sound, and can offer building owners significant savings and payback. Please contact CFS for additional information.

Insulation – Reduced energy consumption and efficient control of building temperature are a benefit of added insulation. The economic payback from the SPF insulation, in a metal building application, may occur in just a few years, so the new roof can actually pay for itself. Many metal roofs also have interior condensation issues, applying only a coating, or another metal skin will not control moisture and condensation as the SPF can. Problems from ice build-up and back-ups can also be eliminated. Additional Savings – The removal of the old roof, or adding a roof structure over the current roof, will add tremendous cost to the project. This can also risk the building’s interior and contents to exposure, leaks and potentially costly damage. The application of a SPF and coating system can be achieved at a fraction of the cost of metal replacement. The insulated roof will make the building more comfortable and efficient as the facility energy cost will be lowered. Also roof surface temperatures can be lowered by 60?F, by installing a reflective, Energy- Star© rated coating, such as Roof-Tek’s Poly-Sil and Acry-Tek. With greater energy efficiency, lowered surface temperatures, eliminating waste from roof a tear-off, and compact and efficient product transport, the SPF System may contribute toward LEED design credits.

Scope of work, typical: Coated SPF over metal

  • Identify current roofing problems
  • Research roof history
  • Inspect roof conditions
  • Repair loose panels and fasteners
  • Preparation of surface, Power wash and apply Prep-Tek, Primer as required
  • Roof-Tek SPF Insulation application
  • Apply Roof-Tek elastomeric coating
  • Inspect to comply with Roof-Tek spec. and warranty issued